Users Online: 401
Home Print this page Email this page
Home About us Editorial board Search Browse articles Submit article Ahead of Print Instructions Subscribe Contacts Login 
ORIGINAL ARTICLE
Year : 2020  |  Volume : 9  |  Issue : 1  |  Page : 51

Clinical Utility of Blood Pressure Measurement Using the Newer Palpatory Method for Both Systolic and Diastolic Blood Pressure


1 MBBS IInd Year Student, AIIMS, Bhopal, Madhya Pradesh, India
2 Department of Physiology, AIIMS, Bhopal, Madhya Pradesh, India
3 Department of Oral Medicine and Radiology, Rishiraj College of Dental Sciences, Bhopal, Madhya Pradesh, India

Correspondence Address:
Dr. Avinash E Thakare
Associate Professor, Department of Physiology, AIIMS, Bhopal, Madhya Pradesh
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/abr.abr_254_19

Rights and Permissions

Background: Blood pressure (BP) measurement being a part of clinical examination gives a fair idea about the hemodynamic status. The auscultatory method is considered as a gold standard, a simple, noninvasive way to measure BP in patients as well as in the healthy controls. The present study was designed to compare systolic BP (SBP) and diastolic BP (DBP) readings using a newer palpatory method with the standard auscultatory method and further assessing the reliability of the newer palpatory method. Materials and Methods: A cross-sectional study comprising of a total of 400 (240 males and 160 females) individuals in the age range of 20–60 years were included in this study. BP measurement was done by the standard auscultatory method by one observer. Another observer blinded with BP records of the auscultatory method, measured BP using the newer palpatory method on the same individuals. The two methods were compared for the inter-rater reliability using intraclass correlation (ICC) statistics and agreement between two methods using Bland–Altman analysis. Results: The present study observed excellent reliability of the newer palpatory method with the standard auscultatory method with an ICC value of 0.997 and 0.993 for SBP and DBP, respectively. Bland–Altman plot for both SBP and DBP using the auscultatory and newer palpatory method has shown minimum variability and good reliability when both methods are used by independent observers. Conclusions: With practice and experience newer palpatory method can be used to assess BP with accuracy.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed120    
    Printed4    
    Emailed0    
    PDF Downloaded24    
    Comments [Add]    

Recommend this journal