LETTER TO EDITOR
Adv Biomed Res 2019,  8:28

Designing and Manufacture of Training Simulator for Injecting and Fluid Removing of Knee Joint


1 Department of Internal Medicine, Isfahan Bone Metabolic Disorders Research Center, School of Medicine, Isfahan University of Medical Sciences, Isfahan, Iran
2 Clinical Skills Training Center, Isfahan University of Medical Sciences, Isfahan, Iran
3 Department of Epidemiology, School of Health, Shiraz University of Medical Sciences, Shiraz, Iran

Date of Web Publication12-Apr-2019

Correspondence Address:
Dr. Amirhosein Salehi
Department of Internal Medicine, Isfahan Bone Metabolic Disorders Research Center, School of Medicine, Isfahan University of Medical Sciences, Isfahan
Iran
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/2277-9175.256046

Rights and Permissions

How to cite this article:
Pakzad B, Karimzadeh H, Dadgostarnia M, Mousavi M, Salehi A, Akbari M. Designing and Manufacture of Training Simulator for Injecting and Fluid Removing of Knee Joint. Adv Biomed Res 2019;8:28

How to cite this URL:
Pakzad B, Karimzadeh H, Dadgostarnia M, Mousavi M, Salehi A, Akbari M. Designing and Manufacture of Training Simulator for Injecting and Fluid Removing of Knee Joint. Adv Biomed Res [serial online] 2019 [cited 2023 Jun 6];8:28. Available from: https://www.advbiores.net/text.asp?2019/8/1/28/256046



Sir,

Joint diseases are common causes of referral of patients to emergency and clinics. Trauma, mechanical pain, and inflammatory joint diseases are the main causes.[1] Joint fluid accumulation is one of the most common manifestations. In most cases, fluid aspiration should be considered to check the cause.[2] In both interventions (drug injection or joint aspiration), sufficient skill is needed to prevent injury to the periarticular tissues.[3] Today, this diagnostic and therapeutic intervention is done by traditional way and under the guidance of ultrasound. General practitioners and residents of internal disease and orthopedics and infectious diseases require appropriate training in this field. Training on medical simulators is known as one of the best educational methods. In many recent studies, the group that trained by the simulators had better results compared to the control group.[4],[5],[6] The knee joint is one of the most commonly involved joints in a variety of joint diseases. We designed and manufactured an Iranian knee tap simulator for medical students to practice joint aspiration or intra-articular injection [Figure 1]. This simulator is designed like a human's knee. Knee anatomy is considered in its design. The parts of this simulator include bones (femur, tibia, fibula, and patella), plastic bands that tie these bones together (as ligaments), and silicone bag located on the knee joint. The fluid is injected through a hose into the bag. A thin aluminum layer covers the joint surface. This layer is connected to an electronic circuit. During the procedure, if the needle hits this layer, the beep sound will generate by the electronic circuit. There is a plenty of soft foam around these complexes instead of the muscles. There is a skin-like silicone layer also covers all of these simulators. All the simulator parts are produced in Iran. The lower price and the existence of an electronic circuit are the main differences between this simulator and the foreign simulators. We thank all the people who helped us in this research, especially the Clinical Training Center of Isfahan University of Medical Sciences.
Figure 1: Knee tap simulator

Click here to view


Acknowledgment

We would like to thank Dr. Tahereh Changiz and Dr. Nikoo Yamani.

Financial support and sponsorship

This study was financially supported by the Deputy of Research of Isfahan University of Medical Sciences (grant).

Conflicts of interest

There are no conflicts of interest.



 
  References Top

1.
Freiberger RH. Technique of knee arthrography. In: Freiberger RH, Kaye JJ, Spiller J, editors. Arthrography. New York: Appleton-Century-Crofts; 1979. p. 5-30.  Back to cited text no. 1
    
2.
Cardone DA, Tallia AF. Diagnostic and therapeutic injection of the hip and knee. Am Fam Physician 2003;67:2147-52.  Back to cited text no. 2
    
3.
Douglas RJ. Corticosteroid injection into the osteoarthritic knee: Drug selection, dose, and injection frequency. Int J Clin Pract 2012;66:699-704.  Back to cited text no. 3
    
4.
Singh SK, Bostrom M, Popa DO, Wiley CW. Design of an interactive lumbar puncture simulator with tactile feedback. In: Proceedings of the 1994 IEEE International Conference on Robotics and Automation. IEEE; 1994. p. 1734-9.  Back to cited text no. 4
    
5.
Moorthy K, Jiwanji M, Shah J, Bello F, Munz Y, Darzi A, et al. Validation of a web-based training tool for lumbar puncture. Stud Health Technol Inform 2003;94:219-25.  Back to cited text no. 5
    
6.
Waikakul S, Vanadurongwan B, Chumtup W, Assawamongkolgul A, Chotivichit A, Rojanawanich V, et al. Aknee model for arthrocentesis simulation. J Med Assoc Thai 2003;86:282-7.  Back to cited text no. 6
    


    Figures

  [Figure 1]



 

Top
Previous article  Next article
 
  Search
 
Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
Access Statistics
Email Alert *
Add to My List *
* Registration required (free)

 
  In this article
References
Article Figures

 Article Access Statistics
    Viewed2176    
    Printed102    
    Emailed0    
    PDF Downloaded277    
    Comments [Add]    

Recommend this journal