ORIGINAL ARTICLE
Adv Biomed Res 2017,  6:117

Clinical Implications of TiGRT Algorithm for External Audit in Radiation Oncology


1 Department of Medical Physics, School of Medicine, Isfahan University of Medical Sciences, Isfahan, Iran
2 Department of Nuclear Engineering, Faculty of Advanced Sciences and Technologies, Isfahan University, Isfahan, Iran

Date of Web Publication21-Sep-2017

Correspondence Address:
Daryoush Shahbazi-Gahrouei
Department of Medical Physics, School of Medicine, Isfahan University of Medical Sciences, Isfahan
Iran
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/abr.abr_268_16

Rights and Permissions
  Abstract 

Background: Performing audits play an important role in quality assurance program in radiation oncology. Among different algorithms, TiGRT is one of the common application software for dose calculation. This study aimed to clinical implications of TiGRT algorithm to measure dose and compared to calculated dose delivered to the patients for a variety of cases, with and without the presence of inhomogeneities and beam modifiers. Materials and Methods: Nonhomogeneous phantom as quality dose verification phantom, Farmer ionization chambers, and PC-electrometer (Sun Nuclear, USA) as a reference class electrometer was employed throughout the audit in linear accelerators 6 and 18 MV energies (Siemens ONCOR Impression Plus, Germany). Seven test cases were performed using semi CIRS phantom. Results: In homogeneous regions and simple plans for both energies, there was a good agreement between measured and treatment planning system calculated dose. Their relative error was found to be between 0.8% and 3% which is acceptable for audit, but in nonhomogeneous organs, such as lung, a few errors were observed. In complex treatment plans, when wedge or shield in the way of energy is used, the error was in the accepted criteria. In complex beam plans, the difference between measured and calculated dose was found to be 2%–3%. All differences were obtained between 0.4% and 1%. Conclusions: A good consistency was observed for the same type of energy in the homogeneous and nonhomogeneous phantom for the three-dimensional conformal field with a wedge, shield, asymmetric using the TiGRT treatment planning software in studied center. The results revealed that the national status of TPS calculations and dose delivery for 3D conformal radiotherapy was globally within acceptable standards with no major causes for concern.

Keywords: TiGRT, treatment planning system, radiation oncology, lung, phantom, dosimetry


How to cite this article:
Shahbazi-Gahrouei D, Saeb M, Monadi S, Jabbari I. Clinical Implications of TiGRT Algorithm for External Audit in Radiation Oncology. Adv Biomed Res 2017;6:117

How to cite this URL:
Shahbazi-Gahrouei D, Saeb M, Monadi S, Jabbari I. Clinical Implications of TiGRT Algorithm for External Audit in Radiation Oncology. Adv Biomed Res [serial online] 2017 [cited 2019 Sep 20];6:117. Available from: http://www.advbiores.net/text.asp?2017/6/1/117/215275


  Introduction Top


Treatment planning system (TPS) is one of the key components of radiation therapy (RT) used widely in the practice of treatment planning and dose computation. Currently, there is a number of planning software with different algorithms to calculate the dose distribution.[1],[2] To take assurance of the treatment quality, the algorithms should be tested to verify its accuracy for dose calculation.[3] Accuracy verification consists set of dosimetry tests, which their results will be compared to the measurements in the phantom.[4],[5],[6],[7] All these operations are defined as the quality assurance (QA) process which should be done after software installation by the TPS users. There is a long history of instruction recommended by the International Atomic Energy Agency (IAEA), in QA of radiotherapy, since 1969.[4] For the purpose of acceptance audit tests, the IAEA has published Technical Reports Series No. 430[8] which provides the general framework and describes a number of tests and procedures to be considered by the TPS users. However, the implementation of all these tests is a costly and laborious procedure. To reduction of this extensive operation to a practical QA process, IAEA has recommended a technical document, TECDOC 1583, which is a set of dedicated practical tests, based on the TRS 430.[8]

In recent years, researchers and TPS users applied different algorithms which have associated advantages and disadvantages in terms of speed of calculation, accuracy, and dealing with inhomogeneities in both tissue structure and density. Laliena Bielsa et al. have used three-dimensional conformal radiotherapy (3DCRT) treatment planning software for photon energies 6 and 15 MV and reported the algorithm has a limitation on nonhomogeneous organs, but a good performance in heterogeneities for high energy X-ray beams is remarkable.[9] Lopes et al. carried out the audit test in 24 centers in Portugal. They recognized known calculation limitations in nonhomogeneous areas such as bone and lung.[10] They did not use the TiGRT TPS and algorithms. In another study, Rutonjsk et al. have been used simple fields and three simple treatment planning algorithms at radiotherapy centers in Serbia.[11] They conducted that using simple TPS caused errors in delivered dose to the patients. Dunn et al. investigated systematic discrepancies between TPS calculated and measured audit doses in regions adjacent to and downstream from low-density material in anthropomorphic and slab phantom geometries using analytical anisotropic algorithm.[12]

The authenticity of the TiGRT TPS calculation has been used by Mesbahi and Dadgar.[13] In their study, only a small beamlet in IMRT is used, and special attention is put on fields that are in the lungs.

To the best of our knowledge, there is no evidence on the assessment of TiGRT in quality control tests in clinical practice, and this work is the first test on the application of this algorithm TPSs. In this study, the TiGRT with a linear accelerator (LINAC; Siemens ONCOR Impression Plus, Germany) to test 3D CRT is evaluated. Finally, this study aimed to report the results of QA process for a commercial TPS, TiGRT (1.0.8.451 Version, Linatech, USA, super convolution-based algorithm), for 3DCRT based on the protocols offered by TECDOC 1583[2] for a variety of cases, with and without the presence of inhomogeneities and beam modifiers.


  Materials and Methods Top


To assist national auditing center, IAEA has been offered a set of guidelines (based on the IAEA TECDOC 1583),[4] specific dosimetry equipment, and intellectual services for medical physicists in RT centers. The audit process was included calculating the dose distribution in phantom by TiGRT treatment planning software and comparing its results with measured values obtaining through a set of clinical test cases. To ensure the accuracy of measurements, the local dosimetry equipment including Farmer ionization chamber and electrometers (Sun Nuclear, USA) was calibrated by the international Secondary Standard Dosimetry Laboratories (SSDLs) before starting the process. Duration test was about 12–14 h and 3 h for all equipment and data processing in the RT centers and only for LINAC, respectively.

Phantom

According to the IAEA-TECDOC 1583, all measurements of clinical test cases were performed on a semi-anthropomorphic thorax phantom named TiGRT quality dose verification or QDV phantom. The phantom is commercially available which is shown in [Figure 1]. It comprised a thoracic body made of different materials associated with thorax components, plastic water-equivalent material (plastic-to-water relative electron density [RED] of 1.003), lung-equivalent material (RED of 0.207), and bone-equivalent material (RED of 1.506), with a marker on the top of it.[12] The phantom contained nine cylindrical holes which were positioned at different locations and were initially filled with solid plugs. For each case of clinical measurements, the corresponding holes were replaced with ionization chambers. The position of the labeled holes is given in [Figure 2].
Figure 1: TiGRT quality dose verification thorax phantom

Click here to view
Figure 2: Position of measurement points in thorax phantom

Click here to view


Computed tomography examinations

The phantom underwent computed tomography (CT) imaging in two times, according to the protocol applied in the local center for a typical thoracic scanning. The CT imaging acquisition parameters such as slice thickness and field of view were kept the same throughout both examinations. The purpose of the first scan was obtaining the CT-to-RED conversion curve of TPS. In this scan, all holes were filled with the reference solid plugs. The local CT-to-RED conversion curve was used for dose calculations. The tolerance value of ± 20 Hounsfield unit was accepted throughout this study.[14] The second scan was done to plan clinical test cases. For this purpose, all reference plugs were replaced with plugs of material corresponding to the regions. After completion of data acquisition from CT workstation, all images in DICOM format were imported to the TiGRT TPS for dose calculation.

Clinical test cases

In total, seven different test cases were accomplished for dose measurements. The goal of these tests was measuring dose value received by holes through the multiple treatment methods which are used in the clinical examination. The explanation for all test cases has described in IAEA-TECDOC 1583.[3] In addition, all these test cases are summarized in [Table 1]. Each clinical test was performed using specific parameters, in which the dose value of certain points needed to be measured. In total, 15 points were measured in whole seven test cases and for each one of them was selected as the reference point. To obtain the value of dose measurement points, the chamber was inserted into the corresponding hole. These points should be out of penumbra region to avoid measurement in high-dose gradients.[3]
Table 1: Seven different test cases were accomplished for dosimetric measurement, which is used in the clinical trials

Click here to view


Furthermore, additional measurement points were selected in the build-up region behind the lung material and at an out of field position in the lung. After audit operation, test cases were planned with 6 and 18 MV photons through the radiation TPS (RTPS). All plans were designed relatively simple, based on asymmetric fields with the use of wedges and inhomogeneities. The monitor unit calculation was done for delivering the prescribed dose of 2 Gy to the reference point. The dose calculations were performed based on the grid size routinely used in the center methods. In this research, the TPS calculation algorithm was model based, similar to the method used by Knöös et al.[14] Model-based algorithms calculated the dose distribution in 3D using convolution kernels and also modeling the indirect natural of dose deposition from photon beams. Changes in lateral electron and photon transport are approximately modeled (with lateral transport).

Measurements

Dosimetric equipment includes Farmer ionization chambers and PC-electrometer (Sun Nuclear, USA) reference class electrometers with the calibration traceable to the international SSDL which employed throughout the audit. Dose measurements were accomplished using the IAEA TRS398 protocol and calculated in the absorbed dose to water.[15] The measurements of lung and bone equivalent substances were done on the opinion that dose values were measured in small equivalent water phantom cavities. To boost measurement accuracy, relative output factors as well as wedge factors in TPSs were measured. Based on the published results, the mean wedge transmission data were a Gaussian distribution with a standard deviation (SD) value of ± 2% in the most models of accelerators. According to these data, a ± 4% action level corresponding to two SDs of the mean value was chosen to evaluate the outliers for relative output factors and wedge factors.[16]


  Analysis of the Results Top


To compare the values obtained through measurements (Dmeas) and TPS calculations (Dcal), the same criteria specified in the IAEA TRS 430 were done.[5] However, due to the limited number of available positions for the dose measurements in the semi-anthropomorphic phantom, dose differences were normalized to the dose measured at the reference point for each test case (rather than to the measurement point – local difference), i.e., the following equation was used:[3],[7]



Which Dmeas, ref indicates dose value measured at the reference point. The agreement criteria for each test case are listed in [Table 1] which depends on the complexity of the test case geometry.


  Results Top


Clinical test cases

The system is used in this audit had supplied CT to RED conversion curves which used for the further procedure.

The differences between the measured and calculated doses for the various measurement points and test cases for studied radiotherapy center and accelerator are presented in [Figure 3] and [Figure 4].
Figure 3: Measurement points for Siemens ONCOR for 6 MV photon beam

Click here to view
Figure 4: Measurement points for Siemens ONCOR for 18 MV photon beam

Click here to view


The verification of basic dosimetry data input into TiGRT TPS was done.

To create conditions fully comply with treatment requirements and to compare the measured and calculated results in clinical conditions, all test cases were done in the RT centers. However, LINAC output parameters, percentage depth dose, dose profile, and the head scatter factors were kept constant. The percentage differences between the measured and calculated doses for the various measurement points and test cases are presented in [Figure 3] and [Figure 4].


  Discussion Top


Before testing audit, some experiments such as compliance light, radiation field, and mechanical test consist of the accuracy of the isocenter in the rotations of gantry, collimators, and couch will be done. The accuracy of the optical ruler with a mechanical device was also examined.

The main advantage of audit test is identifying issues and problems which are not related to algorithm restrictions, whereas the main problem with TPSs is incorrect data entry to the software and is a lack of quality for beam modeling. The errors that occur in the accelerator and the lack of proper calibration software are another problem which causes a deviation between the measured and calculated dose.

In this study, the quality control of multileaf collimators (MLCs) is not performed and hence related errors not accounted. [Figure 3] and [Figure 4] showed that at low energies, the power of calculation software for lung and points out of the field is relatively less. The power of software for computing of higher energies and nonhomogeneous areas is suitable for points out of the field. Efficiency of the TPS for both high and low energies and for homogeneous region was acceptable. Indeed, no change was observed in the accuracy and sensitivity of the TPS. All calculations have been performed in clinical conditions.

The CT-to-RED calibration curves which are good conformity between measured and calculated dose must be updated in all radiotherapy centers. The used phantom includes three nonhomogenized regions that can help to confirm the calculation of the TPS for nonhomogeneous regions, in particular for lung.

The difference between the planned dose and the dose delivered to the patient is very useful and will lead to improve treatment planning methods in the centers.[6] Any significant difference between calculated and measured dose may be related to the promotion of correction accelerator dosimetry data entry software, redundancy calibration curve of CT-to-RED, correct modeling of radiation, and expertise of the limitations of the dose calculation algorithm treatment planning software.

In this study, as all accessories (MLC, wedge, block) used a significant difference between calculated and measured dose was observed compared to unused accessories. For reducing the errors, several approaches such as loose placement of the wedge, attenuation coefficient accelerator table, inaccuracies in placing the patient thermoplastics, and inaccuracies in the correct location reference point for patient are recommended. In experiments that radiation passes through the table in both high and low photon energies, range of motion secondary particles is much wider, and so the collected dose for algorithm may be confusing.

As recommended by IAEA-TECDOC 1583, CIRS phantom needs to eight test cases, but in this study, there was no possibility for measuring case 5 due to using of semi CIRS phantom. Several researchers such as Laliena Bielsa et al.[9] used plastic water phantom with 10 point holes which are different from solid phantom which used in this work. For this reason, comparing the results of this work, no was done with their results.

A few errors which observed here is due to lack of using standard or internal center protocols, no enough phantom setting, lack of performing quality control tests routinely, deviations in the dose calculation TPS for wedges, especially in off-axis situations, and the possibility of errors in the correct place shield. Using of audit test may be reduced errors relevant to mentioned criteria. For this reason, recommendation of doing audit test is a vital in all RT centers.

As new radiotherapy equipment invented and introduced to the community, new treatment methods are developed. Further study including the physics of radiation, and planning will be required. When the dose delivery methods are becoming increasingly more complex, it is possible that health centers may not pass the limits of assurance for radiotherapy treatment.

The audit could also help the users to appreciate the properties, qualities, and operational characteristics of TPSs and to better understand their limitations.

The overall results revealed that the national status of TPS calculations and dose delivery for 3DCRT was globally within acceptable standards with no major causes for concern.

Acknowledgments

The authors thank all of the technicians for providing us technical support required for carrying out this work.

Financial support and sponsorship

This work is a part of PhD thesis which financially supported (Grant No. 394597) by Isfahan University of Medical Sciences.

Conflicts of interest

There are no conflicts of interest.

 
  References Top

1.
Lu L. Dose calculation algorithms in external beam photon radiation therapy. Int J Cancer Ther Oncol 2013;1:01025.  Back to cited text no. 1
    
2.
Ulmer W, Pyyry J, Kaissl W. A 3D photon superposition/convolution algorithm and its foundation on results of Monte Carlo calculations. Phys Med Biol 2005;50:1767-90.  Back to cited text no. 2
    
3.
TecDoc, I. 1583: Commissioning of Radiotherapy Treatment Planning Systems: Testing for Typical External Beam Treatment Techniques. Vienna: International Atomic Energy Agency; 2008.  Back to cited text no. 3
    
4.
Ahnesjö A, Aspradakis MM. Dose calculations for external photon beams in radiotherapy. Phys Med Biol 1999;44:R99-155.  Back to cited text no. 4
    
5.
Nadealian Dastjerdi F, Shahbazi-Gahrouei D, Alamatsaz MH, Baradaran-Ghahfarokhi M. Photoneutron shielding design for an 18 MV Saturne 20 medical linear accelerator. J Isfahan Med Sch 2014;32:1433-43.  Back to cited text no. 5
    
6.
Rezaee V, Shahbazi-Gahrouei D, Monadi S, Saeb M. Evaluation of error doses of treatment planning software using solid anthropomorphic phantom. J Isfahan Med Sch2016;34:908-13.  Back to cited text no. 6
    
7.
Shahbazi-Gahrouei D, Gookizadeh A, Abdolahi M. Comparison of conventional radiotherapy techniques with different energies in treating prostate cancer, employing a designed pelvis phantom. J Med Sci 2008;8:429-32.  Back to cited text no. 7
    
8.
Sharpe MB. IAEA Technical Reports Series No. 430: Commissioning and quality assurance of computerized planning systems for radiation treatment of cancer. Med Phys 2006;33:561.  Back to cited text no. 8
    
9.
Laliena Bielsa V, Millan Cebrian E, Garcia Romero A, Cortes Rodicio J, Villa Gazulla D, Ortega Pardina P, et al. Quality assurance of computerized planning systems for radiotherapy treatments according the IAEA-TECDOC-1583: Application to PCRT3D. Rev Fis Med 2012;13:89-96.  Back to cited text no. 9
    
10.
Lopes MC, Cavaco A, Jacob K, Madureira L, Germano S, Faustino S, et al. Treatment planning systems dosimetry auditing project in Portugal. Phys Med 2014;30:96-103.  Back to cited text no. 10
    
11.
Rutonjski L, Petrovic B, Baucal M, Teodorovic M, Cudic O, Gershkevitsh E, et al. Dosimetric verification of radiotherapy treatment planning systems in Serbia: national audit. Radiat Oncol 2012;7:155.  Back to cited text no. 11
    
12.
Dunn L, Lehmann J, Lye J, Kenny J, Kron T, Alves A, et al. National dosimetric audit network finds discrepancies in AAA lung inhomogeneity corrections. Phys Med 2015;31:435-41.  Back to cited text no. 12
    
13.
Mesbahi A, Dadgar H. Dose calculations accuracy of TiGRT treatment planning system for small IMRT beamlets in heterogeneous lung phantom. Int J Radiat Res 2015;13:345-54.  Back to cited text no. 13
    
14.
Knöös T, Wieslander E, Cozzi L, Brink C, Fogliata A, Albers D, et al. Comparison of dose calculation algorithms for treatment planning in external photon beam therapy for clinical situations. Phys Med Biol 2006;51:5785-807.  Back to cited text no. 14
    
15.
IAEA T. 398. Absorbed Dose Determination in External Beam Radiotherapy: An International Code of Practice for Dosimetry Based on Standards of Absorbed Dose to Water. Vienna International Atomic Energy Agency; 2000.  Back to cited text no. 15
    
16.
TECDOC I. 1540. Specification and Acceptance Testing of Radiotherapy Treatment Planning Systems. Vienna: IAEA; 2007.  Back to cited text no. 16
    


    Figures

  [Figure 1], [Figure 2], [Figure 3], [Figure 4]
 
 
    Tables

  [Table 1]


This article has been cited by
1 Effect of Hypofractionation on Prostate Cancer Radiotherapy
Abolfazl Arabpour,Daryoush Shahbazi-Gahrouei
International Journal of Cancer Management. 2017; In Press(In Press)
[Pubmed] | [DOI]



 

Top
Previous article  Next article
 
  Search
 
Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
Access Statistics
Email Alert *
Add to My List *
* Registration required (free)

 
  In this article
Abstract
Introduction
Materials and Me...
Analysis of the ...
Results
Discussion
References
Article Figures
Article Tables

 Article Access Statistics
    Viewed626    
    Printed20    
    Emailed0    
    PDF Downloaded67    
    Comments [Add]    
    Cited by others 1    

Recommend this journal